Re: Inverter working drop down.
Thanks, for all guys. Opened ticket, also contacted instaler.
- Fri Feb 21, 2025 1:16 pm
- Forum: Customer/End User Help
- Topic: Inverter working drop down.
- Replies: 10
- Views: 5984
Re: Inverter working drop down.
Dave, I found that inverter restarts then voltage higher than 240v. Our energy supplier reports that till 250v are ok for them.
Is it possible adjust inverter to not respond exampl till 230 +/-10%, so tlll 253v.
Also I got the opinion, as I see only 4 min intervals, in that time voltage can be much ...
Is it possible adjust inverter to not respond exampl till 230 +/-10%, so tlll 253v.
Also I got the opinion, as I see only 4 min intervals, in that time voltage can be much ...
- Fri Feb 21, 2025 10:52 am
- Forum: Customer/End User Help
- Topic: Inverter working drop down.
- Replies: 10
- Views: 5984
Re: Inverter working drop down.
Thanks Dave, noted.
- Fri Feb 21, 2025 10:42 am
- Forum: Customer/End User Help
- Topic: Inverter working drop down.
- Replies: 10
- Views: 5984
Re: Inverter working drop down.
here we go:
- Fri Feb 21, 2025 9:06 am
- Forum: Customer/End User Help
- Topic: Inverter working drop down.
- Replies: 10
- Views: 5984
Re: Inverter working drop down.
Dear Dave,
Where is no any error. You see at top right zero. Already shoulds down twice.
Where is no any error. You see at top right zero. Already shoulds down twice.
- Fri Feb 21, 2025 8:24 am
- Forum: Customer/End User Help
- Topic: Inverter working drop down.
- Replies: 10
- Views: 5984
Inverter working drop down.
Dear Sirs,
Inverter located in Eastern Europe. T10-G3 model. Problem that time to time from working any kw randomly drops to 1kw or even 0kw.
It seems that some selfsafe in use.
Voltage AC on all is all three fases arround 237v.
Inverter located in Eastern Europe. T10-G3 model. Problem that time to time from working any kw randomly drops to 1kw or even 0kw.
It seems that some selfsafe in use.
Voltage AC on all is all three fases arround 237v.
- Thu Feb 20, 2025 12:24 pm
- Forum: Home Assistant
- Topic: Integration to Homewizard
- Replies: 0
- Views: 5995
Integration to Homewizard
Hi,
please members confirm to integration Foxess (mark Foxess) to Homewizard Energy, thank You.
https://forms.gle/nPm2kBVMBzNLJgAn8
Thank You.
More information:
https://www.homewizard.com/
Regards,
Darius
please members confirm to integration Foxess (mark Foxess) to Homewizard Energy, thank You.
https://forms.gle/nPm2kBVMBzNLJgAn8
Thank You.
More information:
https://www.homewizard.com/
Regards,
Darius