Hi all
Last night I updated the firmware to manager version 1.70 and master 1.53, which seems to have broken the force charging from the FoxEss Energy Management intergration. I had been using this intergration for some time and it seems more than just a conincidence that it has now stopped working. I've already reached out to FoxEss support and I know the interrgation itself hasn't been updated in some time.
Anyone have any alteratives to FoxEss EM when using HA to automate the start and stop charging?
Thanks
Simon
Usual candidate for this after a firmware update is that the update has enabled the scheduler master switch, even though there may be no schedules set, when this is on the inverter will fight with any controls you send it.
Make sure that this is disabled, easiest way is to use the Energy Stats app, otherwise you have to do it via the website.
Make sure that this is disabled, easiest way is to use the Energy Stats app, otherwise you have to do it via the website.