Fox R100-G2 and CHINT DTSU666 smart meter error code 1285
Hello team

I use the Fox R100-G2 inverter ON GRID and I also use the Zero export option, I do not use batteries

I am trying to eliminate the code -1285 error on my inverter. The Chint DTSU666 is connected to the R100-G2 inverter by connecting the smart meter pins 24 and 25 to the smart meter inverter pins 6 and 7.

In the Chint DTSU666 settings I set
CT= 40 (I use clamps 200:5)
Addr=1
baud=9600
nEt=n34
Pt=1.0
Prot=n1
In the inverter settings
quick settings/R&D(Others)
GridMeterCommunicationCheck=enable
SolarMeterCommunicationCheck=enable
MeterCommunicationCheck=enable
CTRatioEnable=enable
CTRatio=40 (1-9999)
I don't know what I'm doing wrong

Image


If I set it to export limit in the quick settings
Export limit settings
PowerLimitOfGridFeeding=Disable
PowerLimitPrecentOfGridFeeding=100.0 (0-100)%
ExportLimit=0 A
It looks like I'm exporting, and I use the zero export option and it doesn't show me the consumption in my house

Image
Re: Fox R100-G2 and CHINT DTSU666 smart meter error code 1285
I have the same communication problem.
Ive tryed a lot a different configuration, but I cant solve it.
Anyone to help me, please ?
Re: Fox R100-G2 and CHINT DTSU666 smart meter error code 1285
They have good support, you can contact them at the number on whatcap (008617701516776), they solved my problem, they are really good support