Upgraded Datalogger firmware to 1.09 and lost 5s updates
I'm at a bit of a loss. I noticed in the Cloud 2.0 app that I could update the W6 datalogger firmware to v1.09 from v1.08. I had 5s updates working in v1.08 (this firmware on a new install). Pressed update, waited, all went well. No errors. Everything back online.

The issue is, I seem to be on 5 minute updates now.

Has anybody bumped into this before, and do you have a fix?

The documentation says that for 5s updates the firmware needs to be v1.08 or greater.
Re: Upgraded Datalogger firmware to 1.09 and lost 5s updates
A discussion here yesterday: viewtopic.php?p=15050#p15050

The short answer was the 5s refresh took a bit of time to "recover" for me it worked, then stopped working, and recovered a few hours later.
Re: Upgraded Datalogger firmware to 1.09 and lost 5s updates
Thanks.

9 hours later it seems to be back.
Re: Upgraded Datalogger firmware to 1.09 and lost 5s updates
Good to hear, must take some time to settle (no idea why though)
Re: Upgraded Datalogger firmware to 1.09 and lost 5s updates
I also encountered the same issue after upgrading my datalogger from firmware v1.08 to v1.09 this morning. Now my 5-second refresh bubble icon has disappeared and it only updates every 5 minutes. I hope after 9 to 12 hours this feature will come back and work as other users reported.

I also encountered another issue after the firmware update: my battery showed as offline. Luckily, Gemini instructed me to power off the inverter and battery and turn them back on again; this resolved the battery offline issue.